16. Loading at High Temperature
BK0402
BK0603
BK1005
BKH0603
BKH1005
Specified Value
BK1608
BK2125
ARRAY
BKP0603
BKP1005
BKP1608
BKP2125
MCF 0605
MCF 0806
MCF 1210
MCF 2010
CK1608
CK2125
CKS2125
CKP1608
CKP2012
CKP2016
CKP2520
NM2012
NM2520
LK1005
LK1608
LK2125
HK0402
HK0603
HK1005
HK1608
HK2125
HKQ0402
HKQ0603W
BK2010
BK3216
Appearance:No significant abnormality
Impedance change: Within ±30%
Appearance:No significant abnormality
Impedance change: Within ±20%
No mechanical damage.
Inductance change: Within ±20% Q change: Within ±30%
No mechanical damage.
Inductance change: Within ±20%
No mechanical damage.
Inductance change: Within ±30%
No mechanical damage.
Inductance change: Within ±10% Q change: Within ±30%
No mechanical damage.
Inductance change: 0.047~12.0μH: Within ±10% 15.0~33.0μH: Within ±15%
Q change: Within ±30%
No mechanical damage.
Inductance change: Within ±20% Q change: Within ±30%
No mechanical damage.
Inductance change: Within ±10% Q change: Within ±20%
HKQ0603C
HKQ0603S
HKQ0603U
AQ105
BK、BKH、BKP Series、MCF Series:
Temperature : 125±3℃(BK、BKH Series)
: 85±3℃(BKP、MCF Series)
Applied current :Rated current
Duration :500+24/-0 hrs
Recovery :2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
(See Note 1)
Test Methods and
Remarks
LK、CK、CKS、CKP、NM、HK、HKQ、AQ Series:
Temperature : 85±2℃(LK、CK、CKS、CKP、NM Series)
: 85±2℃(HK1608,2125)
: 85±2℃(HK1005, AQ105 operating temperature range-55~+85℃)
: 125±2℃(HK0402, HKQ0402, HK0603, HK1005, HKQ0603S, HKQ0603U, HKQ0603W, HKQ0603C, AQ105
operating temperature range-55~+125℃)
Applied current :Rated current
Duration :500±12 hrs
Recovery :2 to 3 hrs of recovery under the standard condition after the test.(See Note 1)
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20±2℃ of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air
pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.
? This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
i_mlci_reli_e-E02R01